Notes:
5292 AC, 6530 SQ FT, SFR / 2 STORY
7/30/2002 12:00:00 AM
CONTRACTORS NEED TO REGISTER BEFORE BEGINNING ANY WORK.
(08/07/2002 13:09 NJ)
BEAMS=10"W X 28"D. W/12" DIA. PIERS W/(1) #5 REBAR
EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS.
ADD CARBON-MONOXIDE DETECTOR LOCATIONS TO LEGEND & PLANS.
CORRECT FUTURE PLOT PLANS TO MEET 4/2002 CONTRACTORS GUIDELINE REQUIREMENTS.
CO DETECTORS REQ'D 1/1000 SQ FT & 1 INSIDE AT GARAGE/AC SPACE.
MIN ROOF PITCH 4/12.