Notes:
2817 AC, 3669 SQ FT, SFR / 2 STORY
12/22/2002 12:00:00 AM
2. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
17. BEAMS=12"W X 28"D.
23. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
42. ON "0" SET-BACK SIDE OF HOUSE NO METERS OR VENTS ARE ALLOWED. GUTTER DOWNSPOUTS MUST DISCHARGE ONTO SAME PROPERTY.
48. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. STRUCTURAL COL'S MUST BE A MIN. OF 4" X 4" WOOD (OR) 3" O.D. STEEL
54. CSST GAS PIPING PROHIBITED IN FRISCO.
63. RECESSED LIGHT FIXTURES MUST BE 2000 IECC CODE COMPLIANT.
67. 12 SEER REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
(12/22/2002 11:43 JC)Vertical wall shakes must be cement fiber.
(4/21/2003 10:32 NJ) ON HOLD DUE TO PAST DUE WATER ACCOUNTS WITH THE CITY OF FRISCO
(9/25/2003 13:21 CLF)
GENERAL CONTRACTOR CHANGED TO KEYSTONE FROM RCS.