8009 AC, 10886 SQ FT, SFR / 2 STORY
3/30/2004 12:00:00 AM
ADDRESSED CHANGED FROM 2865 BELCLAIRE DR TO 2840 SHENANDOAH PER THE PLANNING & ZONING COMMISSION RECOMMENDED APPROVAL ON 2/24/04.
(01/19/2003 08:39 JC)
2. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
17. BEAMS=12"W X 28"D.
20. W/12" DIA. PIERS W/(1) #5 REBAR
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
37. HEIGHT OF STRUCTURE MUST NOT EXCEED 40'0" FROM AVG. FINISH GRADE TO HIGHEST RIDGE.
46. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
48. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. STRUCTURAL COL'S MUST BE A MIN. OF 4" X 4" WOOD (OR) 3" O.D. STEEL
54. CSST GAS PIPING PROHIBITED IN FRISCO.
63. RECESSED LIGHT FIXTURES MUST BE 2000 IECC CODE COMPLIANT.
66. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
67. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.