Notes:
3002 AC, 3624 SQ FT, SFR / 2 STORY
2/5/2003 12:00:00 AM
2. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
5. BEAMS=8"W X 28"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
46. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
49. STRUCTURAL COL'S MUST BE A MIN. OF 4" X 4" WOOD (OR) 3" O.D. STEEL
50. RISERS MUST BE 7 3/4" MAX. ( - 3/8"+0") TREAD MIN OF 10"..
54. CSST GAS PIPING PROHIBITED IN FRISCO.
62. CORRECT FUTURE PLOT PLANS TO MEET 4/2002 CONTRACTORS GUIDELINE REQUIREMENTS.
63. RECESSED LIGHT FIXTURES MUST BE 2000 IECC CODE COMPLIANT.
67. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
(02/05/2003 08:16 JC)2nd. floor with game room and closet.