Notes:
3543 AC, 4186 SQ FT, SFR / 1 STORY
2/11/2003 12:00:00 AM
2. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
10.BEAMS=10"W X 28"D.
21. W/12" DIA. PIERS W/(2) #5 REBAR
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
42. ON "0" SET-BACK SIDE OF HOUSE NO METERS OR VENTS ARE ALLOWED. GUTTER DOWNSPOUTS MUST DISCHARGE ONTO SAME PROPERTY.
48. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. STRUCTURAL COL'S MUST BE A MIN. OF 4" X 4" WOOD (OR) 3" O.D. STEEL
54. CSST GAS PIPING PROHIBITED IN FRISCO.
63. RECESSED LIGHT FIXTURES MUST BE 2000 IECC CODE COMPLIANT.
67. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
(02/11/2003 16:13 JC)Provide documentation of soils treatment as required by the engineer prior to starting construction. (1) story house w/ 500 sf of attic storage with lighting only.