Notes:
4418 AC, 5644 SQ FT, SFR / 2 STORY
3/22/2003 12:00:00 AM
2. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
4. BEAMS=8"W X 26"D.
20. W/12" DIA. PIERS W/(1) #5 REBAR
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
46. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
48. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. STRUCTURAL COL'S MUST BE A MIN. OF 4" X 4" WOOD (OR) 3" O.D. STEEL
54. CSST GAS PIPING PROHIBITED IN FRISCO.
63. RECESSED LIGHT FIXTURES MUST BE 2000 IECC CODE COMPLIANT.
64. ATTIC VENTILATION PER IRC R.806.2.
67. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
(03/22/2003 14:11 JC)2nd. floor w/ (3) B.R.'s, (2) baths, bonus rm., play rm. and attic access to storage.