Notes:
3950 AC, 5198 SQ FT, SFR / 2 STORY
4/19/2003 12:00:00 AM
2. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
8. BEAMS=10"W X 24"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
35. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
37. HEIGHT OF STRUCTURE MUST NOT EXCEED 40'0" FROM AVG. FINISH GRADE TO HIGHEST RIDGE.
42. ON "0" SET-BACK SIDE OF HOUSE NO METERS OR VENTS ARE ALLOWED. GUTTER DOWNSPOUTS MUST DISCHARGE ONTO SAME PROPERTY.
48. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
54. CSST GAS PIPING PROHIBITED IN FRISCO.
63. RECESSED LIGHT FIXTURES MUST BE 2000 IECC CODE COMPLIANT.
64. STC OF 45 REQ'D BETWEEN UNITS.
67. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
(4/19/2003 11:05 CLF)
SECOND FLOOR WITH 2 BEDROOM AND 2 BATH. THREE CAR TANDOM GARAGE.
MAXIMUM HEIGHT 40'-0" NOT 42'-6".