Notes:
06/30/2003 10:35 JC)
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
17. BEAMS=12"W X 26"D.
21. W/12" DIA. PIERS W/(1) #5 REBAR
26. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
27. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
33. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
45. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
47. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
51. CSST GAS PIPING PROHIBITED IN FRISCO.
58. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
59. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
60. WEBB FLOOR JOIST SYSTEMS AND ROOF TRUSS SYSTEMS MUST BE ENGINEERED (SEALED AND SIGNED AND APPROVED BY THE ENGINEER OF RECORD PRIOR TO SUBMITTAL FOR A BUILDING PERMIT.
(06/30/2003 10:35 JC)Stucco siding is not a masonry product. 2nd. floor exposed net wall area must be a min. of 50% masonry.
6391 AC, 7563 SQ FT, SFR / 2 STORY