Notes:
1- CONTINGENT UPON COMPLIANCE WITH CONDITIONS OF APPROVED FINAL SITE PLAN FROM P+Z & CIVIL ENGG DEPTS, CODE/ LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND ALL CITY REVIEW COMMENTS.2- PROVIDE 1 HR SEPARATION WALL @ DRIVE-THRU CANOPIES AS REQ'D.3- PROVIDE 14' MINIMUM CLEAR HEIGHT UNDER THE CANOPY END WHICH IS PROJECTING OVER THE WASTE-TRUCK LANE AS PER RELATED CITY CRITERIA.4- DUMPER ENCLOSURE TO CONFORM TO CITY CRITERIA & STANDARD DETAILS. ENTIRE LAYOUT & TRUCK OPERATION SYSTEM MUST BE REVIEWED & APPROVED BY THE ENVIRONMENTAL SVCS DEPT. (972-335-5519) PRIOR ANY CONSTRUCTION.5- WALLS & CLG OF ELECT'L ROOM TO BE 1 HR FIRE RATED WITH 1 HR ASSEMBLY DOOR SWINGING OUT AS REQ'D.6- DOORS 107A, 110A, 121A & 125A (SHOWN IN-SWINGING) TO BE SUBSTITUTED WITH APPROVED FOLDING TYPE DOOR ASSEMBLIES AS PER COMMENTS, UNLESS OTHERWISE REQUIRED OR ACCEPTED AS SHOWN (IN WRITING) BY TAS OFFICIALS.7- PROVIDE RECESSED HI/LO DRINKING FOUNTAIN AS REQ'D.8- ENTIRE BLDG TO BE FIRE SPRINKLERED AS REQ'D.9- SUBJECT TO TAS & M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
4261 SQ FT, CNEW / AMERICAN BANK OF TEXAS