Notes:
1- CONTINGENT UPON COMPLIANCE WITH CODE & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND ALL REVIEW COMMENTS.
2- PERMIT NOT VALID UNLESS ASBESTOS DOCUMENTATION (SHELL SURVEY/ NEW CONSTRUCTION ARCHITECT'S STATEMENT) IS SUBMITTED AS PER STATE LEGISLATION.
3- PENDING SUBMITTAL OF LETTER FROM THE ENVIRONMENTAL SVCS DEPT. INDICATING IF THE PRESENT SOLID WASTE CONTAINMENT SYSTEM IS ADEQUATE OR NEEDS RESTAURANT'S UPGRADING AS PER CITY CRITERIA.
4- PENDING SUITABLE CONSTRUCTION DETAILS OF ENTIRE STOREFRONT AS FINALLY SELECTED FROM THE CONCEPTIONALLY SKETCHED SUBMITTED OPTIONS (END OF DEMISING WALLS MUST BE EFFECTIVE 1 HR FIRE/SMOKE CONNECTION TO SOLID NON-GLASS STOREFRONT ELEMENT. GLAZING TO BE DOUBLE-PANE INSULATED. NON COMBUSTIBLE SUPPORT FRAMING AND REQUIRED INSULATION MUST BE SHOWN FOR STOREFRONT WALLS COVERED WITH CEMENT PLASTER AND/OR MASONRY VENEER).
5- PROVIDE 2 HR UL-U438 EXH. SHAFT OR APPROVED FIREWRAPPING FOR KITCHEN HOODS UP TO ROOF.
6- SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
1800 SQ FT, CIFO / CRESCENT CITY BEIGNETS RESTAURANT