Short Description:
2329 AC, 2751 SQ FT, SFR, 1 STORY
Notes:
HARDI-STUCCO NOT PERMITTED FOR MASONRY REQ'T ON 1st FLOOR. CONVENTIAL STUCCO OR OTHER MASONRY MUST CONTACT FOUNDATION IN ALL FUTURE SUBMITTALS.
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
8. BEAMS=10"W X 24"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
30. 1ST FLOOR WINDOW BOX-OUTS ONLY - AREA BOX-OUTS NOT ALLOWED.
35. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
51. "ASCE" REQUIRES BEAM BOTTOM REBAR 5.2.2.3 C.
2329 AC, 2751 SQ FT, SFR, 1 STORY