6533 AC, 7639 SQ FT, SFR / 2 STORY
11/2/2003 12:00:00 AM
. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS5. BEAMS=8"W X 26"D.25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.28. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.35. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.(11/2/2003 09:15 MBW)GRADE BEAMS-(2)#5 REBAR IN ALL BEAM BOTTOMS WITHOUT BEAM STRANDS.SEE ATTATCHED STAIR DESIGN SKETCH."EIFS" NOT ALLOWED ON RESIDENTIAL.OPTIONAL FINISHED ATTIC MUST HAVE FIRE PROTECTION.MAXIMUM STRUCTURE HEIGHTIS 44'0".