Notes:
1- CONTINGENT UPON COMPLIANCE WITH CODE & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
2- SUITE'S DOORS #1, 2 & 7 AND THE WALLS OF RECEPTION AREA MUST BE RATED FOR 2 HR ASSEMBLY SYSTEMS, AS REQ'D BY THE CURRENT CODE, OR MATCH THE EXISTING RATING, IF EXISTING LOBBY'S WALLS OR BLDG'S EXIT PASSAGEWAY SYSTEMS ARE FOUND TO BE OF LOWER RATING (BASED ON PAST CODE'S ALLOWANCES), BUT NOT LESS THAN 1 HR ASSEMBLIES. (FOUNDINGS OF LESS THAN 2 HR CONDITIONS MUST BE REPORTED FOR ON-JOB VERIFICATION BY INSPECTORS).
3- SUITE'S POCKET DOORS MAIN ENTRANCE SYSTEM MUST FULLY COMPLY WITH SEC. 1003.3.1.3.3 (OF CURRENT CODE 2000 IBC) IN ORDER TO BE APPROVED AS VALID EXIT COMPONENT REGARDLESS IF OR WHEN DOORS ARE LEFT OPEN OR CLOSED.
4- SUBJECT TO POSSIBLE ADDITIONAL REQUIREMENTS FROM M.E.P. REVIEWERS, FIRE MARSHAL AND FIELD INSPECTORS.
(9/14/2004 16:43 MBW) ALL SUBCONTRACTORS MUST VALIDATE AND OBTAIN CURRENT REGISTRATION WITH THE CITY PRIOR TO START OF PROJECT.
4000 SQ FT, CIFO / SCHEEF & STONE