Notes:
1- CONTINGENT UPON COMPLIANCE WITH BLDG C0DE & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
2- PENDING SUBMITTAL OF TDLR REGISTRATION NUMBER AS REQ'D.
3- NO DOOR TO BE LESS THAN 3'-0" WIDE.
4- JAG DEMISING WALLS AS NEEDED FOR A VALID 1 HR FIRE/SMOKE CONNECTION TO NEAREST STOREFRONT'S "MULLION" (NOT TO GLASS).
5- NO PLBG ALLOWED INSIDE 1 HR DEMISING WALLS.
6- PROVIDE HI/LO DRINKING FOUNTAIN AS REQ'D.
7- TREATMENT ROOMS WHERE 18" SPACE IS NOT AVAILABLE AT THE LATCH SIDE OF THE IN-SWINGING DOOR, MAY BE ACCESSED THRU ADA-COMPLIANT POCKET-DOOR TYPE AS REQ'D.
8- RESTROOM DOORS MUST SWING OUT TO ALLOW FOR ADA'S LAVATORY CLEARANCE (WHICH REQUIRES A LARGER HALLWAY).
9- RESUBMIT UPDATED 1/4" SCALE FLOOR PLAN, CORRECTED AS PER COMMENTS, WITH EXACT LOCATIONS OF STOREFRONT MULLIONS IN RELATION TO THE END OF DEMISING WALLS & THEIR CORRESPONDING CONNECTION DETAILS AS REQ'D.
10- SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
2000 SQ FT, CIFO / NAIL LAND