Notes:
1- CONTINGENT UPON COMPLIANCE WITH BLDG CODE & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
2- DEMISING WALLS TERMINATING AGAINST GLASS ARE NOT PERMISSIBLE. WALL ENDS MUST BE JAGGED AS NECESSARY TO TERMINATE AGAINST THE NEAREST STOREFRONT'S "MULLION" FOR A VALID "1 HR FIRE/SMOKE CONNECTION" AS REQ'D. TO VALIDATE THIS PERMIT, ENLARGED DETAILS OF WALL CONNECTION TO MULLIONS (AND THEIR CORRELATION WITH THE SECURITY GRILLE'S STRUCT'L TUBING) MUST BE SUBMITTED FOR APPROVAL.
3- HI/LO COMBINATION (BI- LEVEL) DRINK'G FOUNTAIN MUST BE PROVIDED. BOTTLED WATER COOLER WITH CUP DISPENSER SYSTEM IS AN ACCEPTABLE SUBSTITUTION FOR THE LOW LEVEL PART ONLY WHEN ACCOMPANIED BY THE INSTALLATION OF A STANDARD HEIGHT DRINK'G FOUNTAIN AS THE HIGH LEVEL PART OF THE HI/LO SYSTEM. (LOCATION OPTIONAL SUBJECT TO APPROVAL).
4- ALL STOREFRONT GLASS PANELS AROUND THE NEW ENTRANCE SYSTEM AND DOOR MUST BE OF TEMPERED GLASS. DOOR FRAME TO MATCH EXISTING STOREFRONT.
5- SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
1476 SQ FT, CIFO / GEEK SQUAD