Permit Info
Short Description:
*CANCELLED*2845 AC, 3318 SF, SFR / 2 STORY
Expiration Date:
7/29/2005
Notes:
*CANCELLED*2845 AC, 3318 SF, SFR / 2 STORY
7/29/2005 12:00:00 AM
* PERMIT CANCELLED PER FAX RECEIVED BY BUILDER... RESUBMITTED NEW PERMIT APPLICATION, SEE B05-2750. CANCELLATION LETTER ATTACHED TO PERMIT AND FILED WITH OTHER PERMITS.
(7/1/2005 16:44 JM)
01. ***ENERGY STAR***
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
09. BEAMS=10"W X 26"D.
23. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
30. 1ST FLOOR WINDOW BOX-OUTS ONLY - AREA BOX-OUTS NOT ALLOWED.
31. SIDING OVER MASONRY AT SECOND STORY NOT ALLOWED.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
56. LETTERS OF ACCEPTANCE REQUIRED FROM BOTH ENGINEERS FOR CO.
2nd level: game rm.
depth of house is 73' 11"----garage shall be 18'x20' clear of stairs to game rm.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
HERITAGE LAKES #04 & #05
|
APPLICANT | ASHTON WOOD HOMES | (972)490-3255 | | 13800 MONTFORT SUITE 100 | DALLAS, TX 76226 |
OWNER | ASHTON WOOD HOMES | (972)490-3255 | | 13800 MONTFORT SUITE 100 | DALLAS, TX 76226 |
CONTRACTOR | ASHTON WOOD HOMES | (972)490-3255 | | 13800 MONTFORT SUITE 100 | DALLAS, TX 76226 |
HERS PROVIDE | ENERGY SENSE | (214)341-0668 | jason.mcalister@mascocs.com | 11111 PLANO ROAD | DALLAS, TX 75238 |
STRUCT ENG | D & E STRUCTURES CONSULTING EN | (214)741-3095 | sdickson@de-structures.com | 100 N. CENTRAL EXPRESSWAY STE. | DALLAS, TX 75201 |
ELECT. CTR. | SWARTZ ELECTRIC X-01/06 | (972)254-3480 | | 228 IRBY LANE | IRVING, TX 75061 |
MECH. CTR. | RELIANT A/C X-6/2005 | (972)864-9688 | | P.O. BOX 14849 | FT WORTH, TX 76117 |
GEN. CONTR. | ASHTON WOOD HOMES | (972)490-3255 | | 13800 MONTFORT SUITE 100 | DALLAS, TX 76226 |
PLUM. CONT. | ZINNA PLUMBING, INC. X-9/05 | ()- | | 4900 PRESTON | FRISCO, TX |
|
RESIDENTIAL ELECTRIC FEE |
$99.54
|
|
MISCELLANOUS MECHANICAL FEES |
$123.00
|
|
MISCELLANEOUS PLUMBING FEES |
$197.00
|
|
BUILDING PERMIT FEE |
$1,558.75
|
|
FENCE FEE |
$20.00
|
|
Total Fees |
Charged: $1,998.29
Balance Due: $1,998.29
|
There are currently no inspections on this record.
|
INITIAL REVIEW | Diana Torres-Biggers | | 6/26/2005 | | 7/17/2005 |
More Info
|
RESIDENTIAL REVIEW | Jeff Maxwell | Appd w/ Cond | 6/26/2005 | 7/1/2005 | 7/17/2005 |
More Info
|
MISC REVIEW | Diana Torres-Biggers | | 7/29/2005 | 7/29/2005 | 7/29/2005 |
More Info
|