Notes:
1000 SQ FT, CIFO / J DONUTS
3/28/2006 12:00:00 AM
RECIEVED CALL FROM VINCE BEHIER (ABSOLUTE ELECTRIC) ASKED TO BE REMOVED FROM PROJECT.
(10/5/2005 11:31 JRS)
MUST COMPLY WITH HEALTH ORDINANCE #00-03-19 AND SMOKING ORDINANCE #00-12-12.
(10/5/2005 11:31 JRS) A1.01 - PROVIDE LOCATION OF COKE MACHINE AND COFFEE MACHINE. ALL EQUIPMENT MUST BE ANSI-SANITATION APPROVED. REFRIGERATORS MUST BE APPROVED FOR INTENDED USE. NO POTENTIALLY HAZARDOUS FOODS SHALL BE KEPT IN SHOWCASE WITHOUT ANSI-SANITATION APPROVAL. PLEASE PROVIDE MANUFACTURERS SPECIFICATIONS REGARDING HOOD REQUIREMENTS FOR OVEN. BAKERY TABLE MUST MEET MINIMUM STANDARDS. MOUNTED SOAP AND TOWEL DISPENSERS REQUIRED AT ALL HAND SINKS. MOP SINK MUST BE FLOOR MOUNTED. GREASE INTERCEPTOR APPROVED AT 1000 GALLONS. INTEGRAL COVED TILE BASE REQUIRED AT KITCHEN, COUNTER, AND TOILET AREAS. CEILING IN KITCHEN AREA MUST BE IMPERVIOUS AND EASILY CLEANABLE. ALL WALLS IN KITCHEN MUST BE FLOOR TO CEILING IMPERVIOUS AND EASILY CLEANABLE - FRP TYPICAL. WALLS IN TOILET AND COUNTER AREAS MUST BE IMPERVIOUS AND EASILY CLEANABLE TO HEIGHT OF 5 FT. PROVIDE MEANS OF STORING ALL FOODSERVICE ITEMS 6 INCHES OR GREATER ABOVE FLOOR.
A2.01 - SMOKING SIGNAGE REQUIRED IN COMPLIANCE WITH CITY OF FRISCO ORDINANCE #00-12-12. SEE ATTACHED SHEET.
10-25-05 jm)
1. tempered windows within 2' from any door
2. valid 1 hour fire/smoke connection at mullion.
3. 1 hour fire/smoke construction with 6" mtl. studs with 5/8" gypsum type X on both sides upto deck and fire seal upto deck.
4. fully sprinklered.