Notes:
2614 AC, 3223 SF, SFR / 2 STORY
1/9/2006 12:00:00 AM
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
10. BEAMS=10"W X 28"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
59. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
2-#5 REBAR TOP AND BOTTOM OF ALL BEAMS WITHOUT STRANDS.
ENGINEER'S LETTER SIGNED AND SEALED REQUIRED IF RETAINING WALL IS 36" OR GREATER IN HEIGHT.
CITY SIDE WALK MUST MEET CITY REQUIREMENTS.
(7/27/2006 11:09 MEV) BUILDER CAME IN CHANGED PLUMBER FROM ABC PLUMBING TO HORIZON PLUMBING.