Notes:
2166 SQ FT, CIFO / FRISCO INTERNAL MEDICINE
7/27/2006 12:00:00 AM
1. Safety glazing required.
2. Any penetrations on desing wall shall not reduced the 1-hour fire resistance requirements.
3. As per the doctor's letter the x-ray room shall not be finished/built but if they decided to built the x-ray room a medical physicist report is required to be submitted with plans.
4. Receptionist counters shall be 38" maximum height as per ANS 904.2
5. Demising wall shall be of type "X" gypsum board with sound insulation.
CONTINGENT UPON COMPLIANCE WITH REVIEW COMMENTS, CODE REQUIREMENT AND PERTINENT LEGISLATIONS.
SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
REFER TO APPROVED PLANS FOR NOTES.
ALL SUBCONTRACTORS MUST VALIDATE AND OBTAIN CURRENT REGISTRATION WITH THE CITY PRIOR TO START OF PROJECT.