286 AC, 572 SQ FT, MISC / CABANA
7/20/2006 12:00:00 AM
BEAMS=10"W x 30"D; WITH 12"DIA. W/3-#5 REBAR VERTICAL PIERS TO EXTEND 2 FT. INTO ROCK OR 15' DEEP BELOW GRADE BEAMS. DO NOT DOWER PIER TO BEAM.
ALL WORK PERFORMED MUST MEET THE 2003 IRC STANDARDS.
SUBJECT TO FIELD INSPECTION APPROVAL.
CALL (972) 335-5586 FOR INSPECTION.