Notes:
3521 AC,4353 SF, SFR / 2 STORY
8/24/2006 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
06. BEAMS=8"W X 28"D.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
38. RETAINING WALLS 3 FT OR TALLER MUST BE ENGINEERED.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. INSPECTIONS, TESTING, COMPONENT VERIFICATION AND FINAL HERS SCORE BY THE THIRD PARTY RATER PROVIDING THE REM-RATE REPORT.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
2-#4s IN THE BOTTOM OF ALL BEAMS WITHOUT BEAM STRANDS.
2 FLOOR: 2-BED ROOMS, 1-BATH, MEDIA AND GAME ROOM WITH WET BAR.
BASED ON REM-RATE REPORT A/C BEING 3521 SQ.FT.
THE OPTION OF ADDITIONAL BDRM. U/S AND ADDITIONAL BATH WILL NOT BE USED WITH THE UNDERSTANDING THAT A NEW REM-RATE REPORT WILL BE PROVIDED AND FEES PAID TO THE CITY BASED ON ADDITIONAL SQ.FT. IF THE OPTIONS ARE ADDED AT A LATER DATE.