Permit Info
Short Description:
3983 AC, 5103 SF, SFR / 2 STORY********VOID**********
Expiration Date:
12/31/2008
Notes:
3983 AC, 5103 SF, SFR / 2 STORY********VOID**********
9/12/2006 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
09. BEAMS=10"W X 26"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
28. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
36. REM-RATE REPORT MUST INCLUDE OUTSIDE FRESH AIR REQUIREMENT.
38. RETAINING WALLS 3 FT OR TALLER MUST BE ENGINEERED.
40. ON "0" SET-BACK SIDE OF HOUSE NO METERS OR VENTS ARE ALLOWED. GUTTER DOWNSPOUTS MUST DISCHARGE ONTO SAME PROPERTY 5'-0" FROM FOUNDATION.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. INSPECTIONS, TESTING, COMPONENT VERIFICATION AND FINAL HERS SCORE BY THE THIRD PARTY RATER PROVIDING THE REM-RATE REPORT.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
53. UTILITY METER VAULTS ARE NOT ALLOWED IN CONCRETE SURFACES.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
zero side left
must have natural ventilation to hvac units for green bldg.
see note 53
2nd level: 2 bdrm. 2 ba. unfin. attic, exercise rm. & game rm.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
VILLAGES OF STONEBRIAR PARK #2
|
APPLICANT | PAVLIS CUSTOM HOMES | (972)741-0295 | | 12801 NORTH CENTRAL EXPRESSWAY | DALLAS, TX 75243 |
OWNER | PAVLIS CUSTOM HOMES | (972)741-0295 | | 12801 NORTH CENTRAL EXPRESSWAY | DALLAS, TX 75243 |
CONTRACTOR | PAVLIS CUSTOM HOMES | (972)741-0295 | | 12801 NORTH CENTRAL EXPRESSWAY | DALLAS, TX 75243 |
HERS PROVIDE | GUARANTEED WATT SAVER | (405)946-0206 | KELLYPAR@GWSSI.COM | 6444 NW EXPRESSWAY, SUITE 836A | OKLAHOMA CITY, OK 73132 |
STRUCT ENG | CHILDRESS ENGINEERING X-7/07 | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
ELECT. CTR. | GALAXY ELECTRIC INC - X 4/07 | (469)682-1375 | | PO BOX 850631 | MESQUITE, TX 75185 |
MECH. CTR. | KRUGERS HEAT'G & A/C X-08/0 | (972)276-3109 | | 1409 S JUPITER RD | GARLAND, TX 75042 |
GEN. CONTR. | PAVLIS CUSTOM HOMES | (972)741-0295 | | 12801 NORTH CENTRAL EXPRESSWAY | DALLAS, TX 75243 |
PLUM. CONT. | PROFESSIONAL PLUMBERS X-02/200 | (972)429-5575 | | 1322 CENTURY WAY | WYLIE, TX 75098 |
|
RESIDENTIAL ELECTRIC FEE |
$153.09
|
|
MISCELLANOUS MECHANICAL FEES |
$162.50
|
|
MISCELLANEOUS PLUMBING FEES |
$270.00
|
|
BUILDING PERMIT FEE |
$1,983.75
|
|
FENCE FEE |
$20.00
|
|
Total Fees |
Charged: $2,589.34
Balance Due: $2,589.34
|
There are currently no inspections on this record.
|
INITIAL REVIEW | MAC | | 8/31/2006 | | 9/21/2006 |
More Info
|
RESIDENTIAL REVIEW | JM | Approved | 8/31/2006 | 9/12/2006 | 9/21/2006 |
More Info
|