Notes:
2850 SQ FT, CIFO / COUNTRY UNITED-TALON LEAD SERVICES
10/9/2006 12:00:00 AM
PLAN REVIEW COMMENTS;
1. THE COMMON PATH OF TRAVEL MEASURED FROM THE MOST REMOTE POINT IN THE SPACE UNDERCONSIDERATION IS 112 FEET WHICH IS OVER THE ALLOWABLE LENGTH OF 100 FEET WITH SPRINKLER INSTALLED (SEE IBC 1013.3 EXCEPTION 1 ), THEREFORE THE CODE REQUIRES AT LEAST TWO (2) MEANS OF EGRESS SHALL BE PROVIDED (IBC 1014.1). SUBMIT REVISED PLANS SHOWING COMPLIANCE WITH THIS CODE.
2. CONNECTION OF DEMISING WALL TO MULLION SHALL BE FIRE/SMOKE PROOF.
3. SAFETY GLAZING AS REQUIRED IN IBC 2406.
4. ANY WOODS USED IN A TYPE II-B CONSTRUCTION SHALL BE FIRE RETARDANT TREATED WOOD.