Notes:
3353 AC, 3981 SF, SFR / 1 STORY
12/5/2006 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
10. BEAMS=10"W X 28"D.
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
30. 1ST FLOOR WINDOW BOX-OUTS MUST HAVE MASONRY BELOW.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.-------------USE STUCCO LEFT ELEVATION, SIDING CANNOT BE FLUSH WITH BRICK--THIS IS NOT A NEW ITEM.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
49. INSPECTIONS, TESTING, COMPONENT VERIFICATION AND FINAL HERS SCORE BY THE THIRD PARTY RATER PROVIDING THE REM-RATE REPORT.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
DO NOT OVERSPAN 2X6 CEILING JOISTS--SEE IRC 2003 T.802
3 CAR TANDEM GARAGE
3 COURSES OF BRICK UNDER BOX OUT LEFT ELEVATION--NO SIDING FLUSH WITH BRICK, YOU MAY USE STUCCO IN PLACE OF FLUSH SIDING