PLAN REVIEW COMMENTS;
1. APPLICABLE CODES SHALL BE THE 2003 IMC, IPC AND IECC.
2. AS DESIGNED, THE PROPOSED FLOOR PLAN LAYOUT, WITH UNINTERRUPTED OPEN SPACES TOTALING 3,000 SQ. FEET OR MORE (12550 SQFT), WOULD REQUIRE AN ENTRY VESTIBULE (AT LEAST ON 3 EXIT/ ENTRANCE), ACCORDING TO THE ENERGY CODE SECTION 802.3.6 EXCEPTION #4.
3. STORAGE/WAREHOUSE AREA SHALL BE SEPARATED FROM THE MAIN OCCUPANCY (RETAIL/SALES AREA) BY A SMOKE PARTITION CONSTRUCTED FROM FLOOR UPTO ROOF DECK WITH FIRE SAFING/CAULKED ON ALL JOINTS, DOOR SHALL BE EQUIPPED WITH SELF CLOSING DEVICES.
4. SAFETY GLAZING REQUIRED AS PER 2003 IBC 2406.
5. RESTROOMS FLOORS AND WALLS SHALL HAVE A SMOOTH, HARD, AND NON-ABSORBENT SURFACE, STAINED AND PAINTS ARE NOT ACCEPTABLE IN CITY OF FRISCO.
5. FLAME SPREAD RATING AND SMOKE DEVELOPED INDEX SHALL BE 0-75 AND 0-450 RESPECTIVELY FOR ALL WALL AND CEILING INTERIOR FINISHES.
6. PENETRATION OF SMOKE PARTITION BY DUCTS OR OTHER AIR OPENINGS SHALL BE PROVIDED WITH AUTOMATIC SMOKE DAMPERS.
7. THE PROPOSED AIR FABRIC SYSTEM (DUCTSOX) IS NOT ALLOWED IN CITY OF FRISCO UNLESS SUBSTANTIAL TESTED AND APPROVED DOCUMENTS ARE SUBMITTED TO THE BUILDING OFFICIAL FOR APPROVAL.
8. SUBJECT TO ADDITIONAL REQUIRENTS FROM M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
WARNING:
BECAUSE NO COPY OF REVIEWED DWGS IS KEPT BY THE CITY, OWNER, OWNER'S REPRESENTATIVE, AND/OR CONTRACTORS, ARE RESPONSIBLE FOR PRINTING THEIR OWN RECORDS AND MUST BE ABLE TO PROVIDE A REPLACEMENT COPY IN CASE ANY RELEASED MARKED DWG OR PERMIT SET IS LOST, DAMAGED, UNAVAILABLE AT THE JOB SITE OR WHEN RECALLED BY BLDG OFFICIAL. OTHERWISE, CONSTR'N MAY NOT PROCEED UNTIL DWGS ARE RESUBMITTED FOR NEW REVIEW AND ALL RELATED FEES ARE PAID.
14600 SQ FT, CIFO / EURWAY FURNITURE