Notes:
1204 SQ FT, CIFO / EADS
4/3/2007 12:00:00 AM
1. APPLICABLE CODES SHALL BE 2003 ICC CODES - IBC, IMC, IPC, IECC, and IFGC.
2. CONTINGENT UPON COMPLIANCE TO BLDG CODE & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
3. ANY NEW WALL PATCHWORK OR NEW PARTITION ALONG RATED EXIT PATHWAYS MUST BE RATED TO MATCH EXISTING (MIN. 1 HR UL-U465), UP TO UNDERSIDE OF DECK ABOVE (AS APPLICABLE), FULLY FIRE SEALED ON BOTH SIDES AND WITH PROTECTED OPENINGS AS REQ'D. FIRE/SMOKE COMBINATION DAMPERS MUST BE ADDED, OR RELOCATED, AT ANY NEW POINT OF DUCTWORK'S RATED PENETRATIONS & AS ACCEPTABLE TO INSPECTORS.
4. ALL CEILING AND WALL FINISHES SHALL COMPLY WITH 2003 IBC SECTION 803 FOR FLAME AND SMOKE SPREAD INDEX/RATING.
5. ANY WOODS SHALL BE FIRE RETARDANT WOOD ON A TYPE II-B CONSTRUCTION AS REQUIRED BY CITY OF FRISCO.
6. PENETRATION ON A 1-HOUR FIRE RATED DEMISING WALL SHALL NOT BE REDUCED, FIRESTOP SYSTEM SHALL BE INSTALLED AND MATERIALS SHALL BE TESTED IN AN APPROVED ASSEMBLY.
7. NO WORK IS ALLOWED TO BE ADDED TO, OR MODIFIED FROM, WHAT SHOWN IN PERMIT SET, UNLESS FOLLOW-UP REVISIONS ARE SUBMITTED AND APPROVED AS REQ'D.
8. ACCEPTABILITY OF USE, LAYOUT AND TYPE OF CONSTR'N OF NEWLY CREATED SPACES (NOT IDENTIFIED ON PLANS) SUBJECT TO INSPECTOR'S VERIFICATION & APPROVALS.
9. SUBJECT TO ADDITIONAL REQUIREMENTS FROM M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.