Notes:
160 SQ FT, SADD / 1/2 BATH ROOM
7/30/2007 12:00:00 AM
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS
GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR,
WITHIN 3'-0" OF A WALKING SURFACE.
31. SIDING OVER MASONRY AT SECOND STORY NOT ALLOWED.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
35. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
60. BUILDER CAUTION: CONSTRUCTION NOT CONFORMING
TO THE ABOVE PERMIT REQUIRMENTS COULD RESULT IN C.O.
DELAY OR POSSIBLE DENIAL.
NO exhaust fan req'd. current codes---- NEC 99'--IPC 2003---IRC 2003
1 sink, w/c and cabinets
based on T. R 502.5(1) with a bldg. width of 49' w/ a roof, ceiling
and 2 clear span floors & an opening of 4' 7"
{header req'ments} 3--2x10's sandwiched above new door.
spoke to bldr. 8-8-07 and allowed the use of an additional 2x4 wall attached to existing 2x4 wall in lieu of 2x6 wet wall.