Notes:
1725 SQ FT, CALT / CHOPAN GRILL
8/17/2007 12:00:00 AM
1. ADDING 3 COMPARTMENT SINK, NO OTHER CHANGES IN SCOPE OF WORK.
2. MAXIMUM OCCUPANCY LOAD IS 60, MANDATORY SIGN SHALL BE POSTED FOR THIS OCCUPANT LOAD.
3. ANY WOOD SHALL BE FIRE TREATED/RETARDENT.
4. SUBJECT TO FIELD APPROVED INSPECTIONS AND TESTING.
Plumbing ordinance 06-11-114
1. All work subject to field approved inspections and testing.
2. Below grade wasted tie-ins, solvent joint or "mission" type S.S. bands.
3. Below grade piping to be bedded with sand.
4. Trenches to be compacted at backfill.
5. Overhead piping to be hung properly to structure.
6. Floor and hub drains installed with trap primer.
7. No PVC allowed in return air plenums.
8. All connections to existing plumbing shall be accessible at inspection.
9. Water heaters to be installed per IPC 2003 w/local amendments.
10. All soldered joints shall be made with flux conforming to ASTM B813.
11. Bottom fed water heaters shall be installed with vacuum relief valve.
12. Penetrations through fire rated assemblies shall be fire stopped by approved method for material.
13. T&P lines shall be located in a safe location in case of bleed off.