Notes:
2540 SQ FT, CIFO / SIENA MASSAGE
10/11/2007 12:00:00 AM
1. Where a portion of main counter is 36" inches long, a portion of counter must be 36" minimum height to meet ADA req'ments.
2. Hi/Lo drinking fountains req'd.
3. Demising walls to be UL-U465 1 hour fire/smoke construction floor to roof deck, fire seal floor to roof deck.
4. Verify location of roof hatch/fire riser room, each tenant to have individual access from space unless centrally located.
5. Tempered windows/glass where req'd.
6. 1 hour fire/smoke connection to mullion.
7. Interior finishes: Group B, Class C flame spread 76--200, smk. dev. 0--450
8. One treatement room shall be fully ADA compliant. Maintain 3' manuevering capability in each direction around bed.
9. Fully sprinkled, II-B constr. 26 occ. load
10. Subject to fire marshal and city approved inspections and testing.
11. Restroom sinks must be moved to comply with 30" x 48" space, 5' turning radius void due to encroachment by w/c and lavatory. see plans
12. 96' to exit from most remote location. this is within compliance 1013 IBC 2003