Notes:
A- CONTINGENT UPON COMPLIANCE WITH P+Z & CIVIL ENGG APPROVALS OF SITE PLAN, BLDG CODE & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
B- DUMPSTER ENCLOSURE AREAS TO COMPLY WITH CITY CRITERIA'S STANDARD DETAILS AND ALL SYSTEM TO BE APPROVED BY THE ENVIRONM'L DEPT PRIOR STARTING ANY CONSTRUCTION.
C- ALL PARTS OF THE BLDG ENVELOPE MUST MATCH OR EXCEED THE MIN. INSULATION REQUIREMENTS OF IECC, WITH R-11 FOR WALLS, R-20 FOR ROOF.
D- STOREFRONT GLAZING TO BE 1" INSULATED GLASS TO PROVIDE MAX. SHGC=0.6 AND MAX. U=0.7. (MUST CONFORM WITH SAFETY GLASS REGULATIONS. ALSO ANY FUTURE RATED WALL ENDING AT THE STOREFRONT MUST PROVIDE 1 HR FIRE/SMOKE CONNECTION TO THE NEAREST MULLION OR PILASTER).
E- SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
ALL SUBCONTRACTORS MUST VALIDATE AND OBTAIN CURRENT REGISTRATION WITH THE CITY PRIOR TO START OF PROJECT.
1. R-19 minimum insulation above ceiling, their shall remain a sealed building envelope. When suspended ceiling is installed verify R-19 @ ceiling deck.
IECC 2000 802.2.15
2. Interior finishes: IBC 2003 803.5 Group B, Class B flame spread 76-100
smoke developed 0-450.
3. Fully sprinkled.
4. Tempered windows/glass where applicable.
5. Counter height shall be ADA (TAS compliant section 5)
6. Each tenant shall have individual access to mechanical equipment mounted on the roof. This interior hatch shall be fire/smoke sealed. Verify location of fire riser room and roof access.
1850 SQ FT, CIFO / THE CASH STORE