Notes:
A- CONTINGENT UPON COMPLIANCE WITH P+Z & CIVIL ENGG APPROVALS OF SITE PLAN, BLDG CODE & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
B- DUMPSTER ENCLOSURE AREAS TO COMPLY WITH CITY CRITERIA'S STANDARD DETAILS AND ALL SYSTEM TO BE APPROVED BY THE ENVIRONM'L DEPT PRIOR STARTING ANY CONSTRUCTION.
C- ALL PARTS OF THE BLDG ENVELOPE MUST MATCH OR EXCEED THE MIN. INSULATION REQUIREMENTS OF IECC, WITH R-11 FOR WALLS, R-20 FOR ROOF.
D- STOREFRONT GLAZING TO BE 1" INSULATED GLASS TO PROVIDE MAX. SHGC=0.6 AND MAX. U=0.7. (MUST CONFORM WITH SAFETY GLASS REGULATIONS. ALSO ANY FUTURE RATED WALL ENDING AT THE STOREFRONT MUST PROVIDE 1 HR FIRE/SMOKE CONNECTION TO THE NEAREST MULLION OR PILASTER).
E- SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
ALL SUBCONTRACTORS MUST VALIDATE AND OBTAIN CURRENT REGISTRATION WITH THE CITY PRIOR TO START OF PROJECT.
F. TEMPERED WINDOWS/GLASS WHERE APPLICABLE.
G. FULLY SPRINKLED.
H. INTERIOR FINISHES: GROUP--M CLASS--B
FLAME SPREAD ------------26 TO 75
SMOKE DEVELOPED-------0 TO 450
J. DEMISING WALLS SHALL BE RATED 1 HR. FIRE SMOKE CONSTRUCTION, ALL PENETRATIONS THRU DEMISING WALLS SHALL BE FIRE CAULKED.
K. ANY DUCT PENETRATIONS THRU DEMISING WALLS SHALL HAVE FIRE/SMOKE DAMPERS INSTALLED.
L. ALL WOOD BLOCKING SHALL BE (FRT) FIRE TREATED WOOD.
M. WHERE ABOVE CEILING AREA IS USED AS HVAC PLENUM-PVC PIPE & ALL WIRING SHALL BE PLENUM RATED.
833 SQ FT, CIFO /ONE LIFE NUTRITION