Notes:
2214 A/C, SALT / FIRE RESTORATION
6/3/2008 12:00:00 AM
FIRE RESTORATION-----------------------------------------
02. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
26. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
35. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN.
55. FUEL BURNING HOT WATER HEATER INSTALLATION MUST BE CODE COMPLIANT.
58. 2006 IECC & ENERGY STAR COMPLIANCE REQUIRED.
A. EOR LETTER FILED WITH CITY
B. MINIMUM 13 SEER A/C UNIT REQ'D.
C. COMPLETE HOUSE RE-WIRE, 12 AWG MINIMUM COPPER CONDUCTORS.
D. INSPECTOR MAY REQUIRE BID PROPOSAL FROM CONTRACTOR, SOME WINDOWS WILL NOT BE REPLACED PER CONVERSATION WITH JOHN HILL, INSURANCE LIST INDICATES OTHERWISE.
E. ARC-FAULT CKTS. REQ'D. IN EA. BDRM. CARBON MONOXIDE DETECTORS REQ'D.--ALL SMOKIES AND CM DETECTORS MUST BE HARD WIRED IN.
F. MSTR. BATH FIXTURES TO BE REPLACED-----SEE INSURANCE LIST ATTCH'D.
G. EXHAUST FANS TO BE HARD DUCTED THRU ROOF. BOND ALL B-VENTS INCLUDING FIREPLACE STACK.