Notes:
SALT / REPLACING ALL BRICK
7/17/2008 12:00:00 AM
REPLACE STONE/BRICK:
1. ALL WORK PERFORMED MUST MEET THE 2006 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE.
2. SUBJECT TO FIELD INSPECTION APPROVAL.
CALL (972) 292-5386 FOR INSPECTION.
3. WILL REQUIRE INSPECTIONS OF... LENTIL SUPPORT, WEEP HOLES, FLASHING, AND BRICK TIES. BRICK TIES MINIMUM 22 GAUGE. ONE BRICK TIE FOR EACH 3.5 SQ.FT. OF BRICK. WEEP HOLES EVERY 33".
4. ABOVE LENTILS DRILL A 3/8" WEEP HOLE.
5. FOR INSPECTION A MAXIMUM OF 4' IN HEIGHT OF BRICK CONTINUOUS AT PERIMETER OF HOME. ONCE THIS INSPECTION HAS BEEN APPROVED BY A CITY INSPECTOR THE REMAINDER OF BRICK CAN BE PLACED. NO OTHER INSPECTIONS ARE NECESSARY.
6. A #6 OR #8 MIL WRAP OR EQUIVALENT SHALL BE PLACED AT CONCRETE BRICK LEDGE BETWEEN BOTTOM COURSE OF BRICK.
7. NO SIDING TO BE REPLACED ON THIS PERMIT. ANY SIDING TO BE REPLACED MUST BE ADDED AS A REVISION TO THIS PERMIT AND THE SIDING MUST BE A CEMENTIOUS PRODUCT OR ENGINEERED TREATED WOOD PRODUCT.
8. ALL PENETRATIONS THROUGH SHEATHING MUST BE SEALED; I.E. PIPE, WIRE, A/C REFRIGERATION LINES, ETC.
9. TAKE EXTRA PRECAUTIONARY MEASURES WHERE ELECTRICAL METER AND GAS LINE ARE LOCATED.
10. RECOMMENDATION: IF HOSE BIBBS ARE LOCATED BETWEEN BRICK AND SHEATHING THEY SHOULD BE INSULATED WITH ARMA-FLEX.