Permit Info
Short Description:
*EXPIRED*3576 AC, 4273 SF, SFR / 2 STORY
Expiration Date:
7/18/2009
Notes:
*EXPIRED*3576 AC, 4273 SF, SFR / 2 STORY
1/19/2009 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
(1/19/2009 11:15 JC)
2nd. story with (3) bedrooms, (2) baths, game and media rooms.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
GRAYHAWK PH VI & VII
|
APPLICANT | MERCEDES HOMES | (469)718-7200 | | 11494 LUNA RD #210 | FARMERS BRANCH, TX 75234 |
OWNER | MERCEDES HOMES | (469)718-7200 | | 11494 LUNA RD #210 | FARMERS BRANCH, TX 75234 |
CONTRACTOR | MERCEDES HOMES | (469)718-7200 | | 11494 LUNA RD #210 | FARMERS BRANCH, TX 75234 |
HERS PROVIDE | THE NELROD COMPANY | (817)922-9000 | ct@nelrod.com | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | RESIDENTALSERVICE@FOXELECTRIC.COM | PO BOX 13338 | ARLINGTON, TX 76094 |
MECH. CTR. | FRYMIRE ENGINEERING | (972)620-3500 | | 2818 SATSUMA | DALLAS, TX 75226 |
PLUM. CONT. | KEN-MAN PLUMBING | (817)453-8032 | jlane@ken-mancorp.com | 1836 LONE STAR RD | MANSFIELD, TX 76063 |
|
RESIDENTIAL ELECTRIC FEE |
$128.19
|
|
MISCELLANOUS MECHANICAL FEES |
$136.00
|
|
MISCELLANEOUS PLUMBING FEES |
$253.00
|
|
BUILDING PERMIT FEE |
$1,828.75
|
|
FENCE FEE |
$20.00
|
|
Total Fees |
Charged: $2,365.94
Balance Due: $2,365.94
|
There are currently no inspections on this record.
|
INITIAL REVIEW | Michelle Ortega | Accepted | 1/15/2009 | 1/15/2009 | 2/5/2009 |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | Approved as Noted | 1/15/2009 | 1/19/2009 | 2/5/2009 |
More Info
|