Notes:
2:20 JM
88 A/C SQ. FT. ADDED TO ORIGINAL PERMIT SUBMITTED WITH 320 A/C SQ. FT. BDRM. FOR A TOTAL OF 408 SQ. FT.
ORIGINAL PLANS SHALL REMAIN ON SITE FOR INSPECTOR.
ONLY A MAXIMUM OF 3' ENCROACHMENT OF EAVE AT REAR YARD BUILD LINE.
I BDRM. TO BE ADDED NO PLBG. EXCEPT HOSE BIBB TO BE RELOCATED.
BDRM. MUST BE GREEN BUILDING COMPLIANT WITH FRESH AIR DUCT AND HAVING 2 DAMPERS---------ONE AUTOMATIC AND ONE MANUAL--SEE NOTE 49 BELOW.
ALL CONSTRUCTION SHALL BE FIELD VERIFIED AND TESTED.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 24"D.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
044. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN.
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
058. 2006 IECC COMPLIANCE REQUIRED.
A SMOKE DETECTOR REQ'D. IN THE BDRM. AS WELL AS (ALL) OUTLETS SHALL BE ARC-FAULT PROTECTED.
TWO INSPECTIONS REQ'D. BY THE ENGINEER---PRE-POUR AND FRAME.
A FINAL LETTER FROM THE ENGINEER IS REQ'D. TO BE PICKED UP BY THE INSPECTOR AT BUILDING FINAL.
408 SQ FT, SADD / ROOM ADDITION