Notes:
1. MAINTAIN 7' SIDE YARD BUILD LINE. EAVE MAY ENCROACH OVER BUILD LINE A MAXIMUM OF 3'.
2. INSPECTIONS REQ'D:
A. FOOTER
B. FLATWORK --FOR NEW SLAB PORTION
C. MISC. FRAME AND ELECTRICAL ROUGH
D. MISC. BLDG. FINAL
3. TIE LEDGER BD. INTO EXISTING FRAME WALL WITH 1/2"X10" LAGS OR GKS SCREWS, SEE SHEET 8 ON THE PLANS.
4. ALL WORK SHALL BE FIELD VERIFIED AND TESTED.
5. EXTEND GUTTER AND DOWNSPOUTS TO PREVENT CROSS LOT DRAINAGE, FRENCH DRAIN IS PREFERABLE. (SEE DWG). DISCUSS WITH INSPECTOR FOR BEST METHOD.
6. NO CHIMNEY OR OUTDOOR KITCHEN IN SCOPE OF WORK.
7. GFI OUTLETS REQ'D.
8. WHERE EAVE EXTENDS MORE THAN 24" OVER THE BUILD LINE THE PORTION MUST BE SUPPORTED BY 45 DEGREE KICKERS, DIAGRAM ON SHEET 1.
9. PLANS TO REMAIN ON SITE THROUGHOUT CONSTRUCTION.
565 SQ FT, SADD / PATIO COVER & PATIO DOOR