Notes:
SALT / INTERIOR REMODEL
4/13/2010 12:00:00 AM
(4/13/2010 9:39 AM JM)
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
*210 SQ. FT. CONVERTED TO A/C SPACE [SINGLE GARAGE CONVERTED TO A/C].
*NEW TOTAL UNDER ROOF AREA IS 5039, NO FIRE SPRINKLER REQ'MENT.
*A SHEATHING AND LATH INSPECTION ARE REQ'D.
*R311.2.2 5/8" GYP. BD. REQ'D. UNDER STAIR SOFFIT AND AT WALLS [TYPE X].
*R305.1 CEILING HEIGHT MINIMUM IS 7' OVER BATH PLBG. FIXTURES.
*AN ENGINEER INSPECTION IS REQ'D. FOR THE SLAB ADDITION/TOP-COAT PORTION AND ALSO THE FRAME PORTION. UPON APPROVAL FROM THE ENGINEER A MISC. FRAME INSPECTION SHALL BE COMPLETED BY A CITY INSPECTOR.
*A FINAL ENGINEER'S INSPECTION LETTER IS ALSO REQ'D. FOR BLDG. FINAL.
*RED-LINED CITY APPROVED PLANS SHALL REMAIN ON SITE THROUGHOUT CONSTRUCTION TO COMPLETE INSPECTION PROCESS.
*INSPECTION PHONE # IS AT THE BOTTOM OF THE PERMIT PLACARD.
(6/16/2010 3:14 PM MAC)
* REVISION TO PLANS - DEMO OF FIREPLACE(S) IN BEDROOM AND LIVING ROOM.