Notes:
536 AC, 570 SF, SADD / ADD CASITA
5/4/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN.
058. 2006 IECC & ENERGY STAR COMPLIANCE REQUIRED.
* 2 & 10 RULE @ CHIMNEY WILL APPLY IRC 1001.6.
* R-22 @ VAULT.
* NEED SEPARATE PERMIT FOR RETAINING WALL AND FENCE.
* COMBO SMOKE DETECTOR/CARBON MONOXIDE DETECTOR REQ'D. IT WOULD BE A GOOD IDEA TO MOVE IT 10' FROM FIREPLACE....SEE PLANS.
* TEMP'D. GLASS @ NANO WALLS.