Notes:
(5/14/2010 3:18 PM JM)
COMMERCIAL PLAN REVIEW GENERAL NOTES
B10-1073 PERQUEST EXPANSION
SCOPE OF WORK:
DEMO EXISTING OFFICE WALL/ TO ENLARGE OFFICE 503
A. CONTINGENT UPON COMPLIANCE WITH BLDG CODES & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
B. ALL PARTS OF THE BLDG ENVELOPE MUST MATCH OR EXCEED THE MIN. INSULATION REQUIREMENTS OF IECC, WITH R-13 FOR WALLS, R-19 FOR ROOF DECK. DROP-IN CEILING IS NOT PART OF THE ENVELOPE.
C. SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
ALL SUBCONTRACTORS MUST VALIDATE AND OBTAIN CURRENT REGISTRATION WITH THE CITY PRIOR TO START OF PROJECT.
F. INTERIOR FINISHES: GROUP-- B CLASS--B
FLAME SPREAD ------------ 25 TO 76
SMOKE DEVELOPED------- 0 TO 450
I. ALL WOOD BLOCKING SUPPORTING MILLWORK, STANDARDS & EQUIPMENT SHALL BE (FRT) FIRE TREATED WOOD.
1395 SQ FT, CALT / PERQUEST EXPANSION