Permit Info
Short Description:
DENIED**3018 AC, 3677 SF, SFR / 2 STORY
Notes:
DENIED**3018 AC, 3677 SF, SFR / 2 STORY
6/4/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. BEAMS=8"W X 30"D.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
032. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
CROWN RIDGE #2 (CFR)
|
APPLICANT | DR HORTON | (214)607-4244 | | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
OWNER | DR HORTON | (214)607-4244 | | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
CONTRACTOR | DR HORTON | (214)607-4244 | | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | CT@NELROD.COM | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING | (972)620-8204 | TAMI@STRANDSYSTEMS.COM | 2964 LBJ FREEWAY # 312 | DALLAS, TX 75234 |
ELECT. CTR. | DARDEN ELECTRIC | (972)271-5542 | DARDENELECTRIC@MSN.COM | 2326 EXECUTIVE DR | GARLAND, TX 75041 |
MECH. CTR. | RELIANT HEATING AND AIR CONDIT | (817)831-3950 | CHUCK@RELIANTAC.COM | PO BOX 166169 | IRVING, TX 75016 |
PLUM. CONT. | D & M PLUMBING CONTRACTORS | (903)454-3939 | DKEENE5745@AOL.COM | PO BOX 8519 | GREENVILLE, TX 75404 |
|
RESIDENTIAL ELECTRIC FEE |
$110.31
|
|
MISCELLANOUS MECHANICAL FEES |
$123.00
|
|
MISCELLANEOUS PLUMBING FEES |
$211.00
|
|
BUILDING PERMIT FEE |
$1,363.75
|
|
FENCE FEE |
$20.00
|
|
THOROUGHFARE IMPACT FEE |
$1,683.00
|
|
WATER IMPACT FEE |
$388.00
|
|
SEWER IMPACT FEE |
$28.00
|
|
Total Fees |
Charged: $3,927.06
Balance Due: $3,927.06
|
There are currently no inspections on this record.
|
INITIAL REVIEW | Michelle Ortega | | 5/26/2010 | | 6/16/2010 |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | Approved as Noted | 5/26/2010 | 5/26/2010 | 6/16/2010 |
More Info
|
RESIDENTIAL REVIEW | Poley O Birika | Approved as Noted | 6/25/2010 | 6/25/2010 | 7/16/2010 |
More Info
|