Notes:
256 SQ FT, SALT / PATIO COVER, FIREPLACE & CONCRETE
11/9/2010 12:00:00 AM
102. * ALL WORK PERFORMED MUST MEET THE 2006 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDINANCES.
103. SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.
105. *** NEED A FLATWORK INSPECTION BEFORE THE POUR. ***
106. *** NO PLUMBING PERMIT REQUESTED OR ISSUED ***
107. *** FIRE PIT, OUTDOOR KITCHEN (BBQ GRILL, SINK, ETC) NOT REQUESTED OR PERMITTED.
108. * CONCRETE PATIO MUST BE ONE (1') FOOT FROM REAR PROPERTY AND ONE (1') FOOT FROM SIDE PROPERTY LINES.
148. ***LAG BOLT MUST PENETRATE MAIN HOUSE STUD MIN 1 ½".
172. * ALL WORK PERFORMED MUST MEET THE 2006 IRC STANDARDS.
173. SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.
175. * FIREPLACE MUST BE 100% MASONRY.
176. * VENTING AND FLUE MUST MEET MANUFACTURERS SPECIFICATIONS.
177. * MUST MAINTAIN TEN FOOT CLEARANCE FROM ALL COMBUSTABLE ITEMS.
178. * CHIMNEY MUST MAINTAIN A MINIMUM OF 2' IN CLEARANCE (EXCLUDING SPARK ARRESTOR) IN HEIGHT WITHIN A 10' RADIUS OF CHIMNEY.
179. * FOOTER THICKNESS 12" MIN & WIDTH 6" EACH SIDE OF FIREPLACE WALL.