Permit Info
Short Description:
4108 AC, 5010 SF, SFR / 2 STORY
Notes:
4108 AC, 5010 SF, SFR / 2 STORY
6/24/2013 12:00:00 AM
(6/24/2013 8:50 AM JC)
001. COMPLIANCE WITH THE APRIL 5, 2011 ZONING ORDINANCE REQUIRED.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
030. 1ST FLOOR WINDOW BOX-OUTS MUST HAVE MASONRY BELOW.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH GRADES ARE REQUIRED.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
058. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER ENCLOSED SHEET (CZO PG 188).
(6/24/2013 8:50 AM JC)
(MFD)
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
STONEBROOK CROSSING
|
APPLICANT | SHADDOCK HOMES LTD | (972)398-4019 | misty@shaddockhomes.com | 2400 Dallas Parkway Suite 510 | PLANO, TX 75093 |
OWNER | SHADDOCK HOMES LTD | (972)398-4019 | misty@shaddockhomes.com | 2400 Dallas Parkway Suite 510 | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES LTD | (972)398-4019 | misty@shaddockhomes.com | 2400 Dallas Parkway Suite 510 | PLANO, TX 75093 |
HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@stransystems.com | | IRVING, TX 75039 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | fstory@metrotechelectric.com | | WYLIE, TX 75098 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
|
PLAN REVIEW FEE |
$50.00
|
|
THOROUGHFARE IMPACT FEE |
$1,453.00
|
|
WATER IMPACT FEE |
$1,772.00
|
|
SEWER IMPACT FEE |
$1,619.00
|
|
FENCE FEE |
$20.00
|
|
BUILDING PERMIT FEE |
$2,058.75
|
|
MISCELLANEOUS PLUMBING FEES |
$246.00
|
|
MISCELLANOUS MECHANICAL FEES |
$129.50
|
|
RESIDENTIAL ELECTRIC FEE |
$150.30
|
|
Total Fees |
Charged: $7,498.55
Balance Due: $7,498.55
|
There are currently no inspections on this record.
|
INITIAL REVIEW | Michelle Ortega | | 5/17/2013 | | 6/7/2013 |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | DENIED | 5/17/2013 | 5/17/2013 | 6/7/2013 |
More Info
|
MISC REVIEW | Michelle Ortega | | 6/14/2013 | | 7/5/2013 |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | APPROVED AS NOTED | 6/24/2013 | 6/24/2013 | 7/8/2013 |
More Info
|