Skip to main content
{1}
##LOC[OK]##
{1}
##LOC[OK]##
##LOC[Cancel]##
{1}
##LOC[OK]##
##LOC[Cancel]##
Skip to main content
Home
|
Setup an Account
Log In
Public
Contractor
User Name:
Password:
Password:
Remember Me
Forgot Password
/Forgot Username
Permits
Apply / New Permit
Search Permit
Pay Fees
View on Map
Projects
Search Projects
Pay Fees
View on Map
Contractor
Apply For New Registration
Search Contractors
Pay Fees
Properties
Search Property
View on Map
Inspections
Schedule
View on Map
Scheduled
License
Apply for New Licenses
Search Licenses
Renew
Map
View Map
Locate My Address
Shopping Cart
Pay All Fees
Paid Items
Contact
Contact us
PreLoader
Permit Search
Search By
Search By:
PERMIT NO
SITE ADDRESS
CONTRACTOR NAME
PARENT PROJECT NO
Search Operator:
Begins With
Contains
Equals
At Least
At Most
Search Value:
Search More Results
Click here for search examples
Map
Map Frame
No results
Search
Loading...
Permits
Buttons
Search Results
Search Results
Results below
Search Details
Permit #
B14-1521
Permit Info
Site Info
Contacts (9)
Fees $0.00
Inspections(49)
Reviews(5)
Permit Info
Type:
BUILDING
Subtype:
SNEW
Short Description:
6552 AC, 10199 SF, SFR / 2 STORY
Status:
COMPLETED
Applied Date:
4/16/2014
Approved Date:
4/28/2014
Issued Date:
4/29/2014
Finaled Date:
6/22/2015
Expiration Date:
12/19/2015
Notes:
6552 AC, 10199 SF, SFR / 2 STORY
Linked Activities
Linked Activities:
 
Parent Project
Parent Projects
P1990-0008
HISTORICAL
 
Permit(s)
Sub Permits
L15-2702
PLUMBING
EXPIRED
BF15-0097
BACK FLOW
RES LETTER TWO SENT
L14-4232
PLUMBING
EXPIRED
B14-8522
BUILDING
EXPIRED
P14-0462
POOL
COMPLETED
L14-1590
PLUMBING
VOID
Parcel Info
Address:
10 STONEBRIAR WAY
City/State/Zip:
FRISCO, TX, 75034
Property Type
PARCEL
APN:
C934323
Subdivision:
STONEBRIAR CREEK
Tract:
9A
Block:
Lot:
9A
Sect-Twp-Rng:
Lot Size (SF):
2.0666
Linked Activities
Web Links
Attachments
Contact Type
Name
Phone
E-mail
Address
City/State/Zip
APPLICANT
LEWIS & EARLY CUSTOM HOMES
(214)682-7171
bkearley5@verizon.net
ARGYLE, TX 76226
OWNER
FRICKE WILLIAM M III
()-
ADDISON, TX 75001-6417
CONTRACTOR
LEWIS & EARLY CUSTOM HOMES
(214)682-7171
bkearley5@verizon.net
ARGYLE, TX 76226
HERS PROVIDE
ERIC L DAVIS ENGINEERING
(972)564-0592
robp@eldengineering.com
FORNEY, TX 75126
STRUCT ENG
ERIC L DAVIS ENGINEERING, INC
(972)564-0592
ericdavis@eldengineering.com
P O BOX 2637
FORNEY, TX 75126
ELECT. CTR.
ODYSSEY ELECTRIC LLC
(817)269-2750
TLF122@YAHOO.COM
NORTH RICHLAND HILLS, TX 76182
MECH. CTR.
CHAPMAN AIR & HEAT
(214)340-4999
ascutter@chapmanair.com
DALLAS, TX 75238
FIRE CONTACT
GS FIRE PROTECTION, LLC
(214)708-7289
rfrost@gsfireprotectionllc.com
125 Richardson
ALLEN, TX 75002
PLUM. CONT.
TIM LONG PLUMBING INC
(817)439-3629
TIMLONG59@CHARTER.NET
SUITE 900
HASLET, TX 76052
Description
Amount
Paid Date
PLUMBING ROUGH-IN 05/21/2014 BRY
$30.00
8/18/2014
SHEATHING 08/12/2014 CW
$30.00
8/18/2014
RESIDENTIAL ELECTRIC FEE
$5.58
2/27/2015
MISCELLANEOUS BUILDING PERMIT FEES
$439.87
2/27/2015
MISCELLANOUS MECHANICAL FEES
$6.50
2/27/2015
MISCELLANEOUS PLUMBING FEES
$21.00
2/27/2015
PLAN REVIEW FEE
$50.00
2/27/2015
PLUMBING ROUGH-IN 05/15/2014 JTH
$30.00
8/18/2014
PLUMBTOPOUT/MECHRGH 08/21/2014 JTH
$30.00
2/27/2015
CREDIT CARD FEE
$67.72
4/29/2014
CREDIT CARD FEE
$2.40
8/18/2014
CREDIT CARD FEE
$11.66
2/27/2015
FIRE DEPT INSPECTION FEES
$300.39
8/25/2014
SLAB 05/30/2014 REED
$30.00
8/18/2014
2NDS/FRAMING 08/28/2014 TW
$30.00
2/27/2015
FENCE FEE
$20.00
4/29/2014
BUILDING PERMIT FEE
$2,578.75
4/29/2014
MISCELLANEOUS PLUMBING FEES
$308.00
4/29/2014
MISCELLANOUS MECHANICAL FEES
$179.00
4/29/2014
RESIDENTIAL ELECTRIC FEE
$300.39
4/29/2014
Total Fees
Charged:
$4,471.26
Balance Due:
$0.00
Type
Result
Scheduled Date
Time
Completed
Time
More Info
CO/BUILDING FINAL
APPROVED
6/22/2015
6/22/2015
More Info
CO/BUILDING FINAL
CANCELLED
6/19/2015
6/19/2015
More Info
CO/BUILDING FINAL
RES FAILED
6/17/2015
6/17/2015
More Info
PLUMBMECHFINAL
APPROVED
6/16/2015
6/16/2015
More Info
PLUMBMECHFINAL
RES FAILED
6/15/2015
6/15/2015
More Info
UTILITY / ROW
APPROVED
6/11/2015
6/11/2015
More Info
ELECTRICAL FINAL
APPROVED
4/1/2015
4/1/2015
More Info
ELECTRICAL FINAL
CANCELLED
3/27/2015
3/27/2015
More Info
FLATWORK
APPROVED
3/27/2015
3/27/2015
More Info
ELECTRICAL FINAL
CANCELLED
3/26/2015
3/26/2015
More Info
GAS RELEASE
APPROVED
3/26/2015
3/26/2015
More Info
DRY WALL
APPROVED
3/25/2015
3/25/2015
More Info
INSULATION
APPROVED
3/20/2015
3/20/2015
More Info
2NDS/FRAMING
APPROVED
3/19/2015
3/19/2015
More Info
AUTOFIRE SPRK VISUAL
APPROVED
3/19/2015
3/19/2015
More Info
PLUMBTOPOUT AND MECHRGH
APPROVED
3/18/2015
3/18/2015
More Info
PLUMBTOPOUT AND MECHRGH
RES FAILED
3/16/2015
3/16/2015
More Info
PLUMBTOPOUT AND MECHRGH
CANCELLED
3/13/2015
3/13/2015
More Info
ELECTRICAL ROUGH IN
APPROVED
3/12/2015
3/12/2015
More Info
ELECTRICAL FINAL
APPROVED
12/11/2014
12/11/2014
More Info
BRICK/WALL TIES
APPROVED
9/25/2014
9/25/2014
More Info
DRY WALL
APPROVED
9/25/2014
9/25/2014
More Info
INSULATION
APPROVED
9/16/2014
9/16/2014
More Info
LATH
APPROVED
9/16/2014
9/16/2014
More Info
INSULATION
CANCELLED
9/15/2014
9/15/2014
More Info
INSULATION
CANCELLED
9/15/2014
9/15/2014
More Info
2NDS/FRAMING
APPROVED
9/8/2014
9/8/2014
More Info
AUTOFIRE SPRK HYDRO
APPROVED
9/5/2014
9/5/2014
More Info
AUTOFIRE SPRK VISUAL
APPROVED
9/5/2014
9/5/2014
More Info
2NDS/FRAMING
RES FAILED
8/28/2014
8/28/2014
More Info
PLUMBTOPOUT AND MECHRGH
APPROVED
8/27/2014
8/27/2014
More Info
PLUMBTOPOUT AND MECHRGH
CANCELLED
8/26/2014
8/26/2014
More Info
ELECTRICAL ROUGH IN
APPROVED
8/21/2014
8/21/2014
More Info
PLUMBTOPOUT AND MECHRGH
RES FAILED
8/21/2014
8/21/2014
More Info
CAMERA
APPROVED
8/20/2014
8/20/2014
More Info
CAMERA
NOT REQUIRED
8/20/2014
8/20/2014
More Info
SHEATHING
APPROVED
8/19/2014
8/19/2014
More Info
SHEATHING
RES FAILED
8/12/2014
8/12/2014
More Info
T-POLE
APPROVED
6/5/2014
6/5/2014
More Info
CAMERA
CANCELLED
6/3/2014
6/3/2014
More Info
SLAB
APPROVED
6/2/2014
6/2/2014
More Info
SLAB
RES FAILED
5/30/2014
5/30/2014
More Info
PLUMBING ROUGH-IN
APPROVED
5/29/2014
5/29/2014
More Info
PLUMBING ROUGH-IN
CANCELLED
5/28/2014
5/28/2014
More Info
PLUMBING ROUGH-IN
RES FAILED
5/21/2014
5/21/2014
More Info
PLUMBING ROUGH-IN
CANCELLED
5/20/2014
5/20/2014
More Info
PLUMBING ROUGH-IN
RES FAILED
5/15/2014
5/15/2014
More Info
PIER
APPROVED
5/2/2014
5/2/2014
More Info
PIER
CANCELLED
5/1/2014
5/1/2014
More Info
Type
Reviewer
Status
Submitted
Completed
Due Date
More Info
INITIAL REVIEW
Laurie Weddle
4/16/2014
5/7/2014
More Info
RESIDENTIAL REVIEW
Jim Cottone
APPROVED AS NOTED
4/16/2014
4/16/2014
5/7/2014
More Info
FIRE SPRNKLR REVIEW
Jerry Carter
APPROVED
8/12/2014
8/25/2014
8/25/2014
More Info
RESIDENTIAL REVIEW
Jim Cottone
APPROVED AS NOTED
2/19/2015
2/19/2015
3/5/2015
More Info
FIRE SPRNKLR REVIEW
Phillip Forbus
APPROVED AS NOTED
2/25/2015
2/25/2015
2/25/2015
More Info
X
B12-1234
6101 Frisco Square Blvd
Vineyards