Permit Info
Short Description:
4312 AC, 5274 SF, SFR / 2 STORY
Notes:
4312 AC, 5274 SF, SFR / 2 STORY
5/14/2014 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
011. BEAMS=10"W X 26"D.
021. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
027. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
030. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
041. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
042. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
043. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
VILLAGES OF STONELAKE ESTATES, PH 2A
|
APPLICANT | SHADDOCK HOMES LTD | (972)398-4019 | lora@shaddockhomes.com | | PLANO, TX 75093 |
OWNER | SHADDOCK HOMES LTD | (972)398-4019 | lora@shaddockhomes.com | | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES LTD | (972)398-4019 | lora@shaddockhomes.com | | PLANO, TX 75093 |
HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@stransystems.com | | IRVING, TX 75039 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75080 |
ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | fstory@metrotechelectric.com | | WYLIE, TX 75098 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
|
SEWER IMPACT FEE |
$1,619.00
|
|
WATER IMPACT FEE |
$1,772.00
|
|
THOROUGHFARE IMPACT FEE |
$3,083.00
|
|
MISCELLANEOUS PLUMBING FEES |
$263.00
|
|
MISCELLANOUS MECHANICAL FEES |
$139.50
|
|
RESIDENTIAL ELECTRIC FEE |
$158.22
|
|
FENCE FEE |
$20.00
|
|
BUILDING PERMIT FEE |
$2,103.75
|
|
Total Fees |
Charged: $9,158.47
Balance Due: $9,158.47
|
There are currently no inspections on this record.
|
INITIAL REVIEW | Treb Duma | | 5/9/2014 | 5/9/2014 | 5/30/2014 |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | APPROVED AS NOTED | 5/9/2014 | 5/9/2014 | 5/30/2014 |
More Info
|
MISC REVIEW | Carey L Frazier | DENIED | 4/29/2015 | 4/29/2015 | |
More Info
|