Notes:
839 SQ FT, SADD / ADD & REMODEL
11/24/2015 12:00:00 AM
BEDROOM, BATHROOM, MUD ROOM, & PATIO COVER.
(11/25/2015 9:28 AM CLF)
1. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
2. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
3. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
4. CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS.
5. A FORM BOARD SURVEY WILL BE REQUIRED PRIOR TO INSPECTION OF FOUNDATION.
6. BEAMS=10"W X 30"D.
7. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
8. SIDING DIRECTLY OVER MASONRY AT SECOND STORY IS NOT ALLOWED.
9. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
10. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS.
11. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
12. SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.