Permit Info
Short Description:
4234 AC, 5233 SF, SFR / 2 STORY
Expiration Date:
12/30/2016
Notes:
4234 AC, 5233 SF, SFR / 2 STORY
6/30/2016 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (06/18/13) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
034. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
047. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
(6/30/2016 3:42 PM JC)
Grade Beams : 10" w. x 36" d.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
MAINVUE AT PHILLIPS CREEK RANCH PHASE TW
|
APPLICANT | MAINVUE TX LLC | (972)754-0196 | jimmy.johnston@mainvuehomes.com | | PLANO, TX 75024 |
OWNER | MAINVUE TX LLC | (972)754-0196 | jimmy.johnston@mainvuehomes.com | | PLANO, TX 75024 |
CONTRACTOR | MAINVUE TX LLC | (972)754-0196 | jimmy.johnston@mainvuehomes.com | | PLANO, TX 75024 |
HERS PROVIDE | ENERGY INSPECTORS of TEXAS | (469)235-9395 | JMCDONALD@ENERGYINSPECTOR.COM | | PLANO, TX 75071 |
STRUCT ENG | CHILDRESS ENGINEERING SERVICES | (214)451-6630 | tchildress@cesglobal.com | | RICHARDSON, TX 75080 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | MONICAC@FOXELECTRIC.COM | | ARLINGTON, TX 76094 |
MECH. CTR. | TEMPO MECHANICAL SERVICES (mec | (972)579-2000 | danny.buchanan@tempoair.com | | IRVING, TX 75061 |
PLUM. CONT. | HORIZON PLUMBING | (817)461-1117 | POBRIANT@HORIZONPLUMBING.NET | | ARLINGTON, TX 76013 |
|
SEWER IMPACT FEE |
$1,619.00
|
|
THOROUGHFARE IMPACT FEE |
$3,816.00
|
|
WATER IMPACT FEE |
$2,436.00
|
|
PLAN REVIEW FEE |
$50.00
|
|
BUILDING PERMIT FEE |
$2,043.75
|
|
FENCE FEE |
$20.00
|
|
MISCELLANEOUS PLUMBING FEES |
$312.00
|
|
MISCELLANOUS MECHANICAL FEES |
$165.50
|
|
RESIDENTIAL ELECTRIC FEE |
$156.99
|
|
Total Fees |
Charged: $10,619.24
Balance Due: $10,619.24
|
There are currently no inspections on this record.
|
INITIAL REVIEW | DEMETRI JOHNSON | | 6/21/2016 | | 7/11/2016 |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | APPROVED AS NOTED | 6/30/2016 | 6/30/2016 | |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | DENIED | | 1/1/1901 | |
More Info
|