Notes:
25 SQ FT, SALT / FIRE RESTORATION ON FIREPLACE
2/8/2017 12:00:00 AM
***PERMIT FOR REPAIRS TO FIRE DAMAGE FIREPLACE LOCATED IN THE CORNER OF FAMILY ROOM ONLY***
***SEE ENGINEER DETAIL FOR REPAIRS***
172. * ALL WORK PERFORMED MUST MEET THE 2015 IRC STANDARDS.
176. * VENTING AND FLUE MUST MEET MANUFACTURERS SPECIFICATIONS.
177. * MUST MAINTAIN TEN FOOT CLEARANCE FROM ALL COMBUSTABLE ITEMS.
178. * CHIMNEY MUST MAINTAIN A MINIMUM OF 2' IN CLEARANCE (EXCLUDING SPARK ARRESTOR) IN HEIGHT WITHIN A 10' RADIUS OF CHIMNEY.
ELECTRICAL
* ALL WORK PERFORMED MUST MEET THE 2014 NEC AND 2015 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDIANCES.
01. MINIMUM #12 COPPER CONDUCTORS PERMITTED EXCEPT FOR CONTROLS.
02. NO ALUMINIM WIRE PERMITTED OR #14
** A GASLINE PRESSURE TEST IS REQUIRED WHEN ADDING, RELOCATING GASLINE TO AN OUTDOOR OR TO AN INDOOR FIREPLACE **
153. CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS.
173. SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.