001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
016. BEAMS=10"W X 30"D.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
034. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
039. BOTH INTERIOR AND EXTERIOR STAIRS OF 4 RISERS OR MORE REQUIRE A HANDRAIL
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
047. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
053. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF THIS ISSUED BUILDING PERMIT.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
PRAIRIE VIEW PHASE 2A (CFR)
|
APPLICANT | HIGHLAND HOMES | (972)789-3500 | ryoung@hhomesltd.com | 12345 Burnt Prairie | Frisco, TX 75033 |
OWNER | HIGHLAND HOMES | (972)789-3500 | ryoung@hhomesltd.com | 12345 Burnt Prairie | Frisco, TX 75033 |
CONTRACTOR | HIGHLAND HOMES | (972)789-3500 | ryoung@hhomesltd.com | 12345 Burnt Prairie | Frisco, TX 75033 |
ENGINEER | ERIC L DAVIS ENGINEERING INC | (972)564-0592 | ericdavis@eldengineering.com | PO BOX 2637 | FORNEY, TX 75126 |
HERS PROVIDE | FOX ENERGY SPECIALIST / THE NELROD CO | (817)546-0160 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
STRUCT ENG | ERIC L DAVIS ENGINEERING INC | (972)564-0592 | ericdavis@eldengineering.com | PO BOX 2637 | FORNEY, TX 75126 |
ELECT. CTR. | IN CHARGE ELECTRICAL SERVICES LLC | (972)292-1478 | MATTGOLDBERG@IN-CHARGE-ELECTRIC.COM | | LEWISVILLE, TX T5057 |
MECH. CTR. | ADVENT AIR CONDITIONING INC | (972)221-4373 | aramon@adventair.com | | LEWISVILLE, TX 75057 |
PLUM. CONT. | L & S MECHANICAL (plumb) | (214)393-8338 | aschmiat@lsmech.com | | RICHARDSON, TX 75081 |
|
SEWER IMPACT FEE |
$1,350.00
|
|
THOROUGHFARE IMPACT FEE |
$1,510.00
|
|
WATER IMPACT FEE |
$1,315.00
|
|
RESIDENTIAL ELECTRIC FEE |
$114.87
|
|
MISCELLANOUS MECHANICAL FEES |
$146.00
|
|
MISCELLANEOUS PLUMBING FEES |
$249.00
|
|
MISCELLANEOUS BUILDING PERMIT FEES |
$10.00
|
|
FENCE FEE |
$20.00
|
|
BUILDING PERMIT FEE |
$1,708.75
|
|
Total Fees |
Charged: $6,423.62
Balance Due: $6,423.62
|
There are currently no inspections on this record.
|
INITIAL REVIEW | DEMETRI JOHNSON | | 7/13/2017 | | |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | APPROVED AS NOTED | 8/8/2017 | 8/8/2017 | |
More Info
|