Notes:
6/20/2019 4:43:06 PM
REMOVE OLD BRICK FROM EXTERIOR AND REPLACE WITH NEW BRICK.
BRICK / WALL TIES INSPECTION AT 4' HIGH.
1) Clean mortar from behind brick
2) Remove every 3rd brick bottom row
3) Moisture barrier for OSB R703.2
4) Protect Romex Table E3701.4
5) Poly under brick R703.7.5
6) Brick ties R703.7.4
7) Weep holes R703.7.6, R703.7.2.1
REPAIR OF DAMAGE ELECTRICAL METER BASE, BREAKER PANEL BOX AND COMPONENTS SHALL MEET THE 2014 NEC ELECTRICAL CODE. AND 2015 IRC STANDARDS
AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDIANCES.
01. MINIMUM #12 COPPER CONDUCTORS PERMITTED EXCEPT FOR CONTROLS.
02. NO ALUMINIM WIRE PERMITTED OR #14
132. * ALL WORK PERFORMED MUST MEET THE 2015 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE.
150. ALL FACADES (EXTERIOR) MATERIALS MUST REFLECT EARLY 20TH CENTURY TEXAS ARCHITECTURAL STYLES SAME AS THE EXISTING STRUCTURE.
153. CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS.
163. SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION