Permit Info
Short Description:
2964 AC, 3680 SF 2 STORY
Expiration Date:
2/22/2020
Notes:
8/22/2019 1:24:22 PM
***FENCE REQUIREMENTS IN ACCORDANCE WITH SECTION S-4 OF THE FORM-BASED CODES STANDARDS***
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
014. BEAMS=10"W X 28"D.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
033. ALL SIDING,TRIM,SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL.
039. BOTH INTERIOR AND EXTERIOR STAIRS OF 4 RISERS OR MORE REQUIRE A HANDRAIL
042. TEMPERED GLASS REQUIRED AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQUIRED AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS. EMERGENCY/ESCAPE RESCUE OPENINGS SHALL HAVE NET CLEAR OPENING OF GREATER THAN OR EQUAL TO 5.7 SF. MINIMUM NET CLEAR HEIGHT OF 24" AND NET CLEAR WIDTH OF 20" (GRADE FLOOR OR BELOW GREATER THAN OR EQUAL TO 5.0SF).
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEAD WALK AND GARAGE DOOR ENHANCEMENT AND TREATMENT PER THE ENCLOSED DETAIL
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
2ND FLOOR: 2BR, 1BA, GAME, MEDIA.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
VILLAGES OF MAJESTIC GARDENS
|
APPLICANT | CAMBRIDGE HOMES HOLDINGS, LLC IKA TEGRIT | (817)225-5262 | aaron.bailey@cambridgehomes.com | | FRISCO, TX 75034 |
OWNER | GRBK FRISCO, LLC | ()- | | | PLANO, TX 75093-8722 |
CONTRACTOR | CAMBRIDGE HOMES HOLDINGS, LLC IKA TEGRIT | (817)225-5262 | aaron.bailey@cambridgehomes.com | | FRISCO, TX 75034 |
ENGINEER | ERIC DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
HERS PROVIDE | ENERGY INSPECTORS of TEXAS | (469)235-9395 | JMCDONALD@ENERGYINSPECTORS.COM | | MCKINNEY, TX 75070 |
STRUCT ENG | ERIC DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
ELECT. CTR. | L & S MECHANICAL (elec) | (214)393-8338 | CITYREGISTRATION@LSMECH.COM | | RICHARDSON, TX 75081 |
MECH. CTR. | L & S MECHANICAL (mech) | (214)393-8338 | CITYREGISTRATION@LSMECH.COM | | RICHARDSON, TX 75081 |
PLUM. CONT. | L & S MECHANICAL (plumb) | (214)393-8339 | CITYREGISTRATION@LSMECH.COM | | RICHARDSON, TX 75081 |
|
SEWER IMPACT FEE |
$1,619.00
|
8/26/2019
|
WATER IMPACT FEE |
$1,978.00
|
8/26/2019
|
THOROUGHFARE IMPACT FEE |
$3,816.00
|
8/26/2019
|
RESIDENTIAL PLUMBING FEE |
$228.00
|
8/26/2019
|
RESIDENTIAL MECHANICAL FEE |
$139.50
|
8/26/2019
|
RESIDENTIAL FEE |
$110.40
|
8/26/2019
|
FENCE FEE |
$20.00
|
8/26/2019
|
RESIDENTIAL BUILDING PERMIT FEE |
$1,589.40
|
8/26/2019
|
Total Fees |
Charged: $9,500.30
Balance Due: $0.00
|
There are currently no inspections on this record.
|
INITIAL REVIEW | DEMETRI BOULIGNY | ACCEPTED | 8/2/2019 | 8/5/2019 | 8/16/2019 |
More Info
|
RESIDENTIAL REVIEW | CURTIS WINTON | APPROVED AS NOTED | 8/2/2019 | 8/22/2019 | 8/16/2019 |
More Info
|